| Description | Item | |
|---|---|---|
| RF400 CAC168E | HANSEN type No. | |
| 3020607 | HANSEN part No. | |
| / | NSN part No. | |
| Construction | ||
| Copper clad aluminum wire 2.74±0.025 |
Material Diameter, mm |
Inner Conductor |
| Physically foamed PE 7.24±0.20 |
Material Diameter, mm |
Insulation |
| Bonded Al/PET/Al Tape Overlap:≥25%
Tinned copper wire braid 8.08(Nominal) |
1st shield
2nd shield
Diameter, mm |
Outer Conductor |
| Polyethylene(PE) 0.80 10.16±0.20 |
Material Min. thickness, Diameter, mm |
Jacket |
| Mechanical properties | ||
| 25.4 101.6 |
Single Repeated |
Bending radius , mm |
| 73 | Tensile strength, Kg | |
| 0.71 | Crush resistance, kg/mm | |
| -70℃~+85℃ -40℃~+85℃ -40℃~+85℃ |
Store Installation Operation |
Recommend temperature , ℃ |
| Electrical properties | ||
| 4.49 | Inner conductor DC resistance, Ω/Km | |
| 5.61 | Outer conductor DC resistance, Ω/Km | |
| 50±2 | Impedance,Ω | |
| 78 | Capacitance, PF/m | |
| 85 | Propagation velocity, % | |
| 2.5 | DC breakdown voltage, kV | |
| >5×103 | Insulation resistance, MΩ•km | |
| 16 | Peak power, kW | |
| >90 | Screening attenuation, dB | |
| 16.2 | Cut-off frequency, GHz | |
| Attenuation @20℃,dB/100m | ||
|---|---|---|
| Nom. Attenuation | Frequency, MHz | |
| 2.49 | 30 | |
| 3.18 | 50 | |
| 4.92 | 150 | |
| 6.23 | 220 | |
| 8.86 | 450 | |
| 12.80 | 900 | |
| 16.70 | 1500 | |
| 18.40 | 1800 | |
| 19.40 | 2000 | |
| 21.65 | 2400 | |
| 22.00 | 2500 | |
| 24.60 | 3000 | |
| • Maximum attenuation value shall be 105% of the nominal attenuation value | ||
| Return loss | ||
| ≥23 | 50-300MHz | |
| ≥20 | 300-1000MHz | |
| ≥16 | 1000-3000MHz | |
| Environment requirements | ||
| Comply with the RoHS Directive 2011/65/EU and its Subsequent amendments. | ||